24 GHz Altitude Radar H-1000: Product, Interfaces, Setup & Protocols — Technical Guide
24 GHz Altitude Radar H-1000: Product, Interfaces, Setup & Protocols
A complete technical reference for the H-1000 FMCW altitude radar — key specifications, six wiring configurations, host-software debugging, PX4 / ArduPilot integration, data protocols, and troubleshooting FAQs.

At a glance
Product Introduction
The altitude radar uses the latest RF chip, operating in the 24 GHz frequency band and based on FMCW (Frequency Modulated Continuous Wave) technology. It can detect the distance of the nearest or strongest target in real time, with a measurement accuracy of 2 cm. Featuring a compact size and high stability, it meets the integration requirements of various UAV platforms. The dimensions of the finished product are shown in Figure 1.

Figure 1. Dimensions of the finished radar (unit: mm)
If you are integrating this radar into a flight controller, jump to Section 04 — Debugging Methods. If you need the raw data format for your own parser, see Section 05 — Protocol Overview.
Product Parameters
2.1 Technical Features
- Single-board design, compact size, easy for integration;
- Simple and complete interfaces — just connect the power and communication ports to use;
- Based on FMCW technology, enabling high-precision target positioning;
- Real-time obstacle warning based on analysis of raw target data;
- All-weather operation (especially in adverse conditions such as rain, snow, fog, haze, and sandstorms).
2.2 Appearance
The functions of each part of the radar are shown in Figure 2.

Figure 2. Illustration of the finished radar appearance
- Radar body — install as required; note that the front face of the radar must be free of obstructions or interference.
- Pin definition — for details, see Section 03, Product Interfaces.
- Extension cable, one metre long.
- Terminal block — users can adapt connections as needed.
2.3 Performance Parameters
| Parameter | Min. | Typical | Max. | Unit |
|---|---|---|---|---|
| Operating frequency band | 24.00 | — | 24.5 | GHz |
| Transmit power (EIRP) | — | 13 | — | dBm |
| Data output refresh rate | — | 10 | 20 | Hz |
| Operating mode | FMCW | FMCW | FMCW | — |
| Field of view | ||||
| Horizontal field of view (−6 dB) | ±10 | ±10 | ±10 | ° |
| Vertical field of view (−6 dB) | ±7 | ±7 | ±7 | ° |
| Detection characteristics | ||||
| Distance measurement accuracy | H < 40 | H > 40 and H < 300 | H > 300 | m |
| Distance measurement accuracy | 0.1 | 0.5 | 0.005% × H | m |
| Minimum detection distance | 0.3 | 0.3 | 0.3 | m |
| Maximum detection distance | 1000 | 1000 | 1000 | m |
| Dimensions and interfaces | ||||
| Communication interface | UART, RS485, RS232, CAN | — | ||
| Output content | Distance information | — | ||
| Physical dimensions | Refer to Chapter 1 | mm | ||
| Environmental adaptability | ||||
| Operating temperature | −40 | — | 85 | °C |
| Operating humidity | 5% | — | 95% | RH |
| Power supply | ||||
| Operating voltage | 9 | 12 | 24 | V |
| Power consumption | 1.4 | 1.5 | 1.6 | W |
Product Interfaces
The radar supports one UART serial port, one RS485 interface, one RS232 interface, and one CAN interface; all four interfaces support parameter configuration and target output. Because the device is shipped with a 6-core cable, the radar supports output on only two communication interfaces at a time. Users may communicate their shipping requirements to the sales personnel in advance as needed.
For UART and RS232 links, wire RX → TX and TX → RX (cross-connected), and always tie the radar ground to the host / supply ground. Never power the radar from a flight-controller port.
3.1 UART + CAN
Default UART baud rate: 115200 bps. Default CAN baud rate: 500 kbps. The UART requires cross-connection (RX to TX and TX to RX). Wiring is shown in Table 2 and Figure 3.
| No. | Interface | Color | Definition | Corresponding wire |
|---|---|---|---|---|
| 1 | Power input | Red | DC 9–24 V, 1.2 W | Switching power supply 12 V |
| 2 | Power input | Black | GND | Switching power supply 0 V / UART_GND |
| 3 | Communication | White | UART_RX | UART_TX |
| 4 | Communication | Green | UART_TX | UART_RX |
| 5 | Communication | Purple | CAN_H | CAN_H |
| 6 | Communication | Yellow | CAN_L | CAN_L |

Figure 3. UART + CAN mode wiring diagram
3.2 UART + RS485
Default UART and RS485 baud rates: 115200 bps. The UART requires cross-connection. Wiring is shown in Table 3 and Figure 4.
| No. | Interface | Color | Definition | Corresponding wire |
|---|---|---|---|---|
| 1 | Power input | Red | DC 9–24 V, 1.2 W | Switching power supply 12 V |
| 2 | Power input | Black | GND | Switching power supply 0 V / UART_GND |
| 3 | Communication | White | UART_RX | UART_TX |
| 4 | Communication | Green | UART_TX | UART_RX |
| 5 | Communication | Purple | RS485_A | RS485_A |
| 6 | Communication | Yellow | RS485_B | RS485_B |

Figure 4. UART + RS485 mode wiring diagram
3.3 UART + RS232
Default UART and RS232 baud rates: 115200 bps. Both the UART and RS232 require cross-connection. Wiring is shown in Table 4 and Figure 5.
| No. | Interface | Color | Definition | Corresponding wire |
|---|---|---|---|---|
| 1 | Power input | Red | DC 9–24 V, 1.2 W | Switching power supply 12 V |
| 2 | Power input | Black | GND | Supply 0 V / UART_GND / RS232_GND |
| 3 | Communication | White | UART_RX | UART_TX |
| 4 | Communication | Green | UART_TX | UART_RX |
| 5 | Communication | Purple | RS232_RX | RS232_TX |
| 6 | Communication | Yellow | RS232_TX | RS232_RX |

Figure 5. UART + RS232 mode wiring diagram
3.4 RS232 + RS485
Default RS232 and RS485 baud rates: 115200 bps. The RS232 requires cross-connection. Wiring is shown in Table 5 and Figure 6.
| No. | Interface | Color | Definition | Corresponding wire |
|---|---|---|---|---|
| 1 | Power input | Red | DC 9–24 V, 1.2 W | Switching power supply 12 V |
| 2 | Power input | Black | GND | Supply 0 V / RS232_GND |
| 3 | Communication | White | RS232_RX | RS232_TX |
| 4 | Communication | Green | RS232_TX | RS232_RX |
| 5 | Communication | Purple | RS485_A | RS485_A |
| 6 | Communication | Yellow | RS485_B | RS485_B |

Figure 6. RS232 + RS485 mode wiring diagram
3.5 RS232 + CAN
Default RS232 baud rate: 115200 bps; default CAN baud rate: 500 kbps. The RS232 requires cross-connection. Wiring is shown in Table 6 and Figure 7.
| No. | Interface | Color | Definition | Corresponding wire |
|---|---|---|---|---|
| 1 | Power input | Red | DC 9–24 V, 1.2 W | Switching power supply 12 V |
| 2 | Power input | Black | GND | Supply 0 V / RS232_GND |
| 3 | Communication | White | RS232_RX | RS232_TX |
| 4 | Communication | Green | RS232_TX | RS232_RX |
| 5 | Communication | Purple | CAN_H | CAN_H |
| 6 | Communication | Yellow | CAN_L | CAN_L |

Figure 7. RS232 + CAN mode wiring diagram
3.6 RS485 + CAN
Default RS485 baud rate: 115200 bps; default CAN baud rate: 500 kbps. Wiring is shown in Table 7 and Figure 8.
| No. | Interface | Color | Definition | Corresponding wire |
|---|---|---|---|---|
| 1 | Power input | Red | DC 9–24 V, 1.2 W | Switching power supply 12 V |
| 2 | Power input | Black | GND | Switching power supply 0 V |
| 3 | Communication | White | RS485_A | RS485_A |
| 4 | Communication | Green | RS485_B | RS485_B |
| 5 | Communication | Purple | CAN_H | CAN_H |
| 6 | Communication | Yellow | CAN_L | CAN_L |

Figure 8. RS485 + CAN mode wiring diagram
Debugging Methods
The radar supports parameter configuration and visualized waveform debugging through the company’s debugging software via a serial port or CAN connection. It can also be connected to PX4 and ArduPilot flight controllers for real-world data testing.
4.1 Debugging Instructions
4.1.1 Host software download
The download link for the debugging software is as follows. Users can select the latest version to download (the software supports only Windows platforms); the software is ready to use after extraction.
Cloud drive: Altitude Radar Software
Link: https://pan.baidu.com/s/1z13yoI5oeBLjBYX7X6JKzg?pwd=4naf Extraction code: 4naf
4.1.2 Required test tools
- Laptop / PC
- Altitude radar
- Switching power supply
- USB debugger: USB-to-UART / USB-to-RS232 / USB-to-RS485 / USB-to-PCAN
- Software driver for the corresponding USB debugger
- Other cables and adapters
4.2 Software Debugging
4.2.1 Serial device connection
After opening the software, the interface is shown in Figure 9. Connect the radar following the steps below:
- Select the corresponding product model.
- Wire according to Section 03, Product Interfaces, and select the corresponding connection method.
- For a serial connection using UART, RS232, RS485, etc., select the corresponding COM port and baud rate, click Connect, and wait for the version number to appear in the lower-left corner.
- After clicking Connect, the appearance of the version number in the lower-left corner indicates a successful connection. Click Read to obtain the radar parameters.

Figure 9. Serial connection interface
4.2.2 CAN device connection
After opening the software, the interface is shown in Figure 10. Connect the radar following the steps below:
- Select the corresponding product model.
- Wire according to Section 03, Product Interfaces, and select the CAN connection method.
- For a CAN connection, click Refresh, select the corresponding CAN device and baud rate, click Connect, and wait for the version number to appear in the lower-left corner.
- After clicking Connect, the appearance of the version number in the lower-left corner indicates a successful connection. Click Read to obtain the radar parameters.

Figure 10. CAN connection interface
4.2.3 Interface description
After the radar is connected successfully, the interface is shown in Figure 11.

Figure 11. Host software debugging interface
- Radar Connection — Switch the connection method, select the corresponding parameters, and then connect the device.
- Radar Basic Information — Displays a configurable character string that records radar-related information. Click Read to obtain the current radar information; click Set to write the currently displayed information to the radar.
- Port Configuration — Displays the parameters of the radar output interface. Click Read to obtain the current radar parameters; click Set to configure the currently displayed parameters on the radar.
- Detection Parameters — Displays the current radar parameters. Click Read / Set to obtain or configure them. The configuration parameters are as follows:
- Device ID — affects the output of certain protocols.
- COM Communication Protocol — modifies the protocol currently enabled for serial output.
- CAN Communication Protocol — modifies the protocol currently enabled for CAN output.
- Detection Period — affects the detection frequency and output frequency.
- Display Mode — modifies the waveform display under the debugging protocol.
- Serial Port Enable — enables the serial port; checked means output, unchecked means no output.
- Measured Height — parses the output data of the connected port according to the communication protocol in the detection parameters.
- Height Value — displays the current radar height.
- Height Confidence — displays the confidence level of the current radar height value.
- Line Chart — records changes in the height value and plots a line chart.
- View Echo Data — displays the current radar echo data.
- Data Save — when checked, saves the height or waveform to a local file.
- System Upgrade — upgrades the radar firmware; for details, see the Firmware Upgrade Manual.
- Other — displays some other information, such as current time, online status, version information, status prompts, and the current connection port.
4.3 Connecting to a PX4 Flight Controller
4.3.1 Installing QGroundControl
Official link: https://qgroundcontrol.com/
4.3.2 QGroundControl configuration
Connect the flight controller, open the configuration options, and under Parameters → sensors → SENS_TFMINI_CFG, select the input interface of the rangefinding device, such as TELEM2. Under the same menu, select TFMINI, as shown in Figure 12.
Connect the radar device to the selected
TELEM2 interface. Do not power the device from the flight-controller interface, and ensure a common ground between the radar and the controller.

Figure 12. PX4 configuration interface
4.3.3 Modifying radar parameters
Set the radar serial parameters to 115200, 8, n, 1, and select the TF03 protocol.
4.3.4 Viewing radar data
As shown in Figure 13, open the Analyze Tools option in QGC and view the current distance value under MAVLink Inspection → DISTANCE_SENSOR → current_distance. Unit: cm.

Figure 13. PX4 monitoring interface
4.4 Connecting to an ArduPilot (APM) Flight Controller
4.4.1 Downloading and installing Mission Planner
Official link: https://firmware.ardupilot.org/Tools/MissionPlanner/
4.4.2 Mission Planner parameter configuration
In the full parameter list, find and configure the following parameters:
RNGFND1_ORIENT = 25(downward)RNGFND1_TYPE = 20SERIAL2_PROTOCOL = 9SERIAL2_BAUD = 115200(select according to your wiring and the radar baud-rate configuration)
After writing the above items, click Write Parameters and wait for the configuration interface to refresh. Then set:
RNGFND1_MIN_CM = 30RNGFND1_MAX_CM = 20000(configure according to the radar model)
4.4.3 Modifying radar parameters
Set the radar serial parameters to 115200, 8, n, 1, and select the TF03 protocol.
4.4.4 Viewing radar data
Select the rangeFinder1 data to display on the page, or view it on the Status page, as shown in Figures 14 and 15.

Figure 14. ArduPilot data page

Figure 15. ArduPilot status page
Protocol Overview
5.1 UART (COM) Protocol Overview
The COM protocol is a protocol for serial output via UART, RS485, RS232, etc. It sends data through the enabled transmit interface according to the configured protocol. Regardless of the protocol used, any of the three interfaces can connect to the host computer through the corresponding USB converter.
5.1.1 SZY protocol
The debugging protocol uses hexadecimal data messages in little-endian byte order. In the table, U8 denotes the char type, U16 the unsigned short type, and S16 the short type. The radar outputs height data once per cycle; the data format is shown in Table 8.
| Data field | Byte count | Valid value | Remarks |
|---|---|---|---|
| Message header | 2 | "SZ" |
— |
| Message type | 1 | 13 | — |
| Data length | 1 | 4 | — |
| Height | 3 | — | Height value, unit: mm, big-endian |
| Confidence | 1 | — | — |
| Checksum | 2 | — | CRC16 MODBUS checksum, little-endian; see the appendix |
Example:53 5A 0D 04 00 00 00 00 0F FA
53 5A— message header0D— message type 1304— data length00 00 00— height00— confidence0F FA— checksum value
5.2 CAN Protocol Overview
The CAN protocol is a protocol for output via the CAN port. It sends data according to the configured CAN protocol, and any protocol can connect to the host computer.
5.2.1 CAN_SZY protocol
The debugging protocol uses hexadecimal data messages in little-endian byte order. The radar outputs height data once per cycle; the data format is shown in Table 9.
| Data field | Byte count | Valid value | Remarks |
|---|---|---|---|
| CAN ID | 2 | 0x535 |
Default value, configurable via the host computer |
| Message header | 2 | "SZ" |
— |
| Data length | 1 | 3 | — |
| Height | 3 | — | Height value, unit: mm, big-endian |
| Checksum | 2 | — | CRC16 MODBUS checksum, little-endian; see the appendix |
Example:ID = 0x535, Data = 53 5A 03 00 00 00 54 31
0x535— CAN ID53 5A— message header03— data length00 00 00— height54 31— checksum
Precautions
- Adequate electrostatic protection must be observed during radar transportation, storage, operation, and handling. When handling a standalone, non-integrated module, note that electrostatic protection should begin as soon as the module is removed from its sealed anti-static packaging.
- Do not touch or grasp the radar antenna surface or the connector pins; only touch the edges and corners. It is recommended to wear anti-static gloves whenever handling any radar sensor.
- Do not wrap the antenna with metal foil or any partially metallic material; do not wrap the antenna with CFK sheets (which are conductive).
- Do not spray the antenna structure with any kind of paint or varnish.
- Do not allow plastic materials to come into direct contact with the antenna structure (a high dielectric constant affects the resonant frequency of the patch).
- When installing the radar, ensure that the module faces vertically downward so as to guarantee accurate detection data.
- When installing the radar, keep it away from electromagnetic interference sources such as motors and suspended metal housings.
- When installing the radar, keep it away from other radars to avoid mutual interference between radars operating in the same frequency band.
The antenna face must be completely unobstructed — nothing may be placed beneath the radar that could block or reflect the beam.
Frequently Asked Questions
Double-clicking RadarConfigTool.exe fails to open the software and a pop-up message appears.

Figure 16. DirectX_Repair software interface
The converter is plugged in, but the host debugging software does not show a COM port / CAN card.

Figure 17. Device Manager interface
A port appears in Device Manager but cannot be opened in the host debugging software.

Figure 18. Host software “Access Denied” interface
After opening the serial port, the software does not display the height and reading other parameters produces no response.

Figure 19. Host software “Timeout” interface
The serial port shows green (connected) in the lower-right corner, but the height value is 0 or does not change.

Figure 20. Host software parameter reading interface
Appendix 1 — CRC16 MODBUS Checksum
The following C implementation generates the CRC16 MODBUS checksum used by the protocol frames in Section 05.
void InvertUint16(unsigned short* dBuf, unsigned short* srcBuf)
{
int i;
unsigned short tmp[4];
tmp[0] = 0;
for (i = 0; i < 16; i++)
{
if (srcBuf[0] & (1 << i))
tmp[0] |= 1 << (15 - i);
}
dBuf[0] = tmp[0];
}
unsigned short CRC16_MODBUS(u8* data, u8 datalen)
{
unsigned short wCRCin = 0xFFFF;
unsigned short wCPoly = 0x8005;
int i = 0;
InvertUint16(&wCPoly, &wCPoly);
while (datalen--)
{
wCRCin ^= *(data++);
for (i = 0; i < 8; i++)
{
if (wCRCin & 0x01)
wCRCin = (wCRCin >> 1) ^ wCPoly;
else
wCRCin = wCRCin >> 1;
}
}
return wCRCin;
}
Setup Checklist
- Radar mounted level beneath the UAV, antenna facing vertically downward, with a clear, unobstructed field of view.
- Wiring correct for the chosen interface pair — RX/TX crossed where required and grounds tied together.
- PX4:
SENS_TFMINI_CFGset to the selected port (e.g.TELEM2) andTFMINIprotocol; radar at115200, 8, n, 1. - ArduPilot:
SERIAL2_PROTOCOL = 9,SERIAL2_BAUD = 115200,RNGFND1_TYPE = 20,RNGFND1_ORIENT = 25, plus appropriate MIN / MAX CM values. - Live altitude verified in QGroundControl (
DISTANCE_SENSOR) or Mission Planner (rangeFinder1).